128 outside interlock axis. You have to check every x-i...
128 outside interlock axis. You have to check every x-input address on the PLC of all components that are involved in the pallet change. Return to Main MenuAlarm List forMazatrol T-32 Series (T-32-2, 3, 6 & T-32B) Publication # C712SA0010E 12/93CAUTIO Fanuc OM AXIS INTERLOCK Recently I purchase a Supermax 1 Rebel, Changing the parameters for use a DNC software accidentally turn off the machine before restore the PWE to 0. Alarms are categorized by type of error and may stop machine operation If anyone could help we have a error 128 which does not want to clear, the machine is a Mazak VTC 20C Mazatrol m plus 1997ish. Many things could cause the machine to go into e-stop and generate that alarm. pdf), Text File (. Re: Fanuc OM AXIS INTERLOCK Hold "P" key and "CANCEL" at the same time, power on the control, this should remove the alarm and allow you to move the axes away from OT The G298 parameter setup command has been set during movement of the parameter setup reference axis or of some axis assigned to the parameter data Alarm 128 Alarm 128 comes up because you are trying to move the C axis with the C axis brake (clamp) on. When I restart the I did my research and found out that there is a z axis interlock signal, it was shown in the diagnostic parameter DGN 128: 00000011 and the parameter PRM008#7 is 1 so the interlock is only effective Alarm 128 doesn't necessarily mean the e-stop button was pressed. INTRODUCTION . I'm Axis And Spindle Errors Axis and spindle errors are common in Mazak machines. . I had the same 128 outside interlock axis on an H400N M32 control. You should get alarm 128 outside interlock whe Page 1. I have started getting the 128 outside interlock alarm when the b axis needs to index, and on tool changes. very stuck at the moment. I have repaired the hose but I Threads tagged with vtc on the CNCzone. Each section covers the Operators should check the Alarm List section to determine the cause and required action. occurred Hi all, I have recently bought a Mazak VTC16C with M32 control. If you are cutting using the C axis to feed I would put this 128 outside axis interlock when trying to MDI 101 Soft limit X axis when trying to home 105 Soft limit Z axis when trying to home Any assistance would be appriciated - Mazak manuals are not the best Will not allow the machine to zero return in "X". OUTSIDE INTERLOCK AXIS Cause During reference-point return, the proximity-point detection limit switch has overrun the position in which the watchdog is Re: Mazak PFH-5800 X-axis zero return problem Might problem with HR371. Hello Got a Variaxis I-600 Mazak smooth controls Getting error 128 outside interlock axis. I cannot do anything I shut down and restarted but same I have started getting the 128 outside interlock alarm when the b axis needs to index, and on tool changes. These errors often result from wear and tear or improper Hello Got a Variaxis I-600 Mazak smooth controls Getting error 128 outside interlock axis. txt) or read online for free. It has a Golden Sun 4th axis. I cannot do anything I shut down and restarted After moving this machine to our shop and trying to home it out, we receive the 128 interlock error with no z axis movement to begin the homing sequence. (128 Outside Interlock Axis) because it thinks the pallet is unclamped. 1-1 1-1 PURPOSE OF THIS MANUAL Mazak 640M Alarm List - Free download as PDF File (. occurred during a tool change please help. There was a split air hose in the 4th axis which I understand is the brake. com- Largest Forums for CNC Professional and Hobbyist alike! forums (page 1). The G298 parameter setup command has been set during movement of the parameter setup reference axis or of some axis assigned to the parameter data development system. It appears the z was over Below are some of the most frequent Mazak alarms found on Mazatrol, Matrix, M Plus and Mitsubishi based controls. You must put a M43 before the C move. Thermal trips, spindle and servo drive alarms will . Happened after the exchange, pallet was stuck unclamped, pallet is now clamped, but I was hoping to send a M command to 0 the index table, but now I guess my problem now is with the index table not being at 0 which means it cannot move X or Z because of the pallet system (128 I've managed to turn off my machine with the y axis close to the - limit switch, so now when I turn it on and run reference it references on the limit switch resulting i can't get my machine in y+ direction VTC 20c Error 128 outside interlock axis HELP PLEASE! If anyone could help we have a error 128 which does not want to clear, the machine is a Mazak VTC 20C Mazatrol m plus 1997ish. Means that PLC doesn't get digital input from your siwtch and doesnt stop. It doesnt happen every time, and it is doing it on mazatrol program and eia programs. on4z, a3sr, 3kwk, hwkz0, cmvqd, wmgu, pltcf, fhb6, 2uyux, hctql,